11-818-100     Precision Instrument Pressure Regulator

    11-818, R27

11-818   

·         Precision instruments with integral pilot to ensure very close pressure control in a compact form

·         Unit double filters air before reaching pilot valve to help prevent leakage and malfunction

·         Panel mounting facility

 

 R27

·         High precision regulator using a control chamber instead of a spring, so increasing its sensitivity to any variations and eliminating any spring hysteresis

·         Perfect for dead-end applications

·         Excellent long term stability

Technical Data

Medium: 11-818 Compressed Air, R27 oil free air filter to 25µm

Maximum Inlet Pressure: 11-818 Low Pressure: 8 bar, 11-818 Standard Pressure 10 bar, 11-818 High Pressure 14 bar, R27: 10 bar (minimum 0,2 above output)

Ambient Temperature: 11-818: 0 to +70°C,  R27: -20°C to +70°C

Models

11-818 Series

Model No:

Port Size

Outlet pressure range

Flow*(dm³/s)

Accuracy

(bar)

Operation

Gauge Ports

Tamper proof adjusting screw

11-818-999

G1/4

0,02 to 0,50(low)

 

0,01

Relieving

-

-

11-818-998

G1/4

0,02 to 0,50(low)

 

0,01

Relieving

-

Tamper proof

11-818-100

G1/4

0,07 to 4(standard)

8,0

0,03

Relieving

-

-

11-818-101

G1/4

0,07 to 4(standard)

8,0

0,03

Relieving

-

Tamper proof

11-818-110

G1/4

0,04 to 10 (high)

 

0,05

Relieving

-

-

11-818-987

G1/4

0,02 to 0,50 (low)

 

0,01

Relieving

R1/4

-

11-818-993

G1/4

0,07 to 4 (standard)

8,0

0,03

Relieving

R1/4

-

11-818-991

G1/4

0,04 to 10(high)

 

0,05

Relieving

G1/4

-

 

Accessories

Model No:

Panel Mount Nut

Service Kit

11-818-999

3081-01

2787-96

11-818-998

3081-01

2787-96

11-818-100

3081-01

2787-98

11-818-101

3081-01

2787-98

11-818-110

3081-01

2787-97

11-818-987

3081-01

2787-96

11-818-993

3081-01

2787-98

11-818-991

3081-01

2787-96

 

R27 Series

Model No:

Port Size

Outlet Pressure Range

Flow*(dm³/s)

Hysteresis/repeatability

Sensitivity

Operation

Gauge Ports

R27-200-RNCG

G1/4

0,14 to 2,0 bar

8,0

<0,05%

>0,3 mbar

Relieving

G1/4

R27-200-RNFG

G1/4

0,14 to 4,0 bar

8,0

<0,05%

>0,3 mbar

Relieving

G1/4

R27-200-RNLG

G1/4

0,14 to 8,0 bar

8,0

<0,05%

>0,3 mbar

Relieving